Key Words:
Current,Transformer§Current,Sensor§Flexible,Current,Transformer§Flexible,Coil,Current,Sensor§AC,Current,Transformer,Probe§Testing,Tool
Package List:
1 x
Current Sensor
Features:
1、The flexible coil current sensor is composed of a coil and a handle. The coil part has no exposed metal conductors. It is non contact measurement, safe and reliable. 2、It is small in size, light in weight, exquisite in appearance, soft and flexible, and is suitable for narrow environments and places with dense cables. 3、Using advanced Rogowski coil technology, it is a toroidal coil that is evenly wound on a non ferromagnetic material, with no hysteresis effect, almost zero phase error, no magnetic saturation, and extremely high linearity. 4、The output signal is the differentiation of current to time. By integrating the output voltage signal, the input current can be truly restored, and the measurement current range can be from milliampere level to tens of thousands of amperes. 5、Durable, wide measurement range, high accuracy, strong reliability, bandwidth response frequency (0.1Hz‑1MHz), made of high quality ABS material, long service life, long term use.
Specification:
Item Type: Current SensorMaterial: ABSModel: ETCR50FAUses: Electronics industry, power communications, equipment manufacturing, power grid maintenance
Function
AC leakage current, large current, high-order harmonic current, complex waveform current, transient inrush current, phase, electric energy, power,Power factor and other detection
Detection method
Flexible coil CT: The output signal is the differentiation of current to time. By integrating the output voltage signal, it can be truly restored input Current
Coil diameter
Φ7.5mm
Measuring range
0A~10000A~higher
Resolution
10mA
Accuracy grade
±1.0%FS (50Hz/60Hz: 23℃±2℃, below 70%RH, the wire is at the center of the coil)
Phase error
≤0.1°(50Hz/60Hz: 23℃±2℃)
Output interface
3.5mm audio frequency plug/BNC plug/tap (optional), cable length 2M
Electric field interference
No hysteresis effect, free from external electric field interference
Wire position
The wire to be tested is at the center of the coil, and the position error affects ≤±0.3%FS
Current frequency
45Hz~70Hz (frequency of measured current)
Response frequency
0.1Hz~1MHz
Line voltage
AC 1000V or less line test
Working temperature and humidity
-20℃~50℃: below 80%rh
Storage temperature and humidity
-10℃~60℃: below 70%rh
Insulation strength
AC 2000V/rms (both ends after the coil is unlocked)
Production Compliance
CAT IV 600V ,CAT Ⅲ 1000V
Product Image: